{"id":1532,"date":"2026-10-04T15:50:37","date_gmt":"2026-10-04T14:50:37","guid":{"rendered":"https:\/\/beleuchtung.vision\/wiki-led\/eye-safety\/"},"modified":"2026-11-21T09:03:14","modified_gmt":"2026-11-21T08:03:14","slug":"eye-safety","status":"publish","type":"br_wikiled","link":"https:\/\/beleuchtung.vision\/en\/wiki-led\/eye-safety\/","title":{"rendered":"Eye Safety"},"content":{"rendered":"<div class=\"br-as225-article\" data-article-version=\"2.25\">\n<p>Industrial LED lighting systems specifically generate high light intensities to make contours, surfaces, and the smallest features visible. In addition to image quality, the safety of the persons who operate, set up, clean, or maintain a system must also be taken into account.<\/p>\n<p>Optical radiation can damage the eyes and skin depending on the wavelength, intensity, and duration of exposure. Perceived brightness alone is therefore not a reliable measure for safe application. This is especially true for ultraviolet and infrared radiation, which is not visible to humans. <a href=\"https:\/\/www.lia.nrw.de\/themengebiete\/Arbeitsschutz\/physikalische_einwirkungen\/Optische_Strahlung\/index.html\">Information on optical radiation \u2013 LIA NRW<\/a><\/p>\n<h2>How is photobiological safety evaluated?<\/h2>\n<p>An essential basis is DIN EN 62471 &#8220;Photobiological safety of lamps and lamp systems.&#8221; It distinguishes four risk groups from the Exempt Group RG0 to Risk Group RG3. Different photobiological hazards are evaluated, for example, from UV radiation, blue light, and thermal effects.<\/p>\n<p>A risk group specification applies to the underlying test and operating conditions. These include, in particular, the viewing distance and the duration of exposure. It should therefore not be understood as an unrestricted statement for any installation situation. <a href=\"https:\/\/www.baua.de\/DE\/Angebote\/Publikationen\/Praxis-kompakt\/F90.pdf?__blob=publicationFile&#038;v=7\">LEDs and Risk Groups \u2013 BAuA<\/a><\/p>\n<h2>What do the risk groups mean for the application?<\/h2>\n<p>The following overview links the classification with possible protective measures. Which measures are actually required results from the evaluation of the specific application.<\/p>\n<figure class=\"br-as225-figure\" style=\"margin:1.5rem 0\"><a href=\"https:\/\/beleuchtung.vision\/wp-content\/uploads\/2026\/11\/augensicherheit-risikogruppen-2-25.png\" target=\"_blank\" rel=\"noopener\" aria-label=\"\u00dcbersicht der vier Risikogruppen vergr\u00f6\u00dfern\"><img decoding=\"async\" class=\"wp-image-1453\" src=\"https:\/\/beleuchtung.vision\/wp-content\/uploads\/2026\/11\/augensicherheit-risikogruppen-2-25.png\" alt=\"Four photobiological risk groups: RG0 Exempt Group, RG1 Low Risk, RG2 Moderate Risk, and RG3 High Risk. The classification only applies under the respective evaluation conditions.\" width=\"1600\" height=\"920\" style=\"display:block;max-width:100%;height:auto\" loading=\"lazy\" srcset=\"https:\/\/beleuchtung.vision\/wp-content\/uploads\/2026\/11\/augensicherheit-risikogruppen-2-25.png 1600w, https:\/\/beleuchtung.vision\/wp-content\/uploads\/2026\/11\/augensicherheit-risikogruppen-2-25-300x173.png 300w, https:\/\/beleuchtung.vision\/wp-content\/uploads\/2026\/11\/augensicherheit-risikogruppen-2-25-1024x589.png 1024w, https:\/\/beleuchtung.vision\/wp-content\/uploads\/2026\/11\/augensicherheit-risikogruppen-2-25-768x442.png 768w, https:\/\/beleuchtung.vision\/wp-content\/uploads\/2026\/11\/augensicherheit-risikogruppen-2-25-1536x883.png 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/a><figcaption style=\"font-size:.9em;margin-top:.5em\">Orientation on the risk groups according to DIN EN 62471. The specific installation situation must be assessed separately.<\/figcaption><\/figure>\n<div class=\"br-as225-table\" role=\"region\" aria-label=\"Risikogruppen und m\u00f6gliche Schutzma\u00dfnahmen\" tabindex=\"0\" style=\"max-width:100%;margin:1.5rem 0\">\n<table style=\"width:100%;min-width:620px;border-collapse:collapse\">\n<thead>\n<tr>\n<th scope=\"col\" style=\"text-align:left;padding:12px;border-bottom:2px solid #dbe2e9\">Risk Group<\/th>\n<th scope=\"col\" style=\"text-align:left;padding:12px;border-bottom:2px solid #dbe2e9\">Meaning under the respective evaluation conditions<\/th>\n<th scope=\"col\" style=\"text-align:left;padding:12px;border-bottom:2px solid #dbe2e9\">Possible measures in industrial applications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\" style=\"padding:12px;text-align:left;border-bottom:1px solid #dbe2e9\">RG0 \u2013 Exempt Group<\/th>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">Under the underlying conditions, there is no photobiological hazard.<\/td>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">Observe manufacturer specifications and evaluation distance. Nevertheless, avoid glare and distracting reflections.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"padding:12px;text-align:left;border-bottom:1px solid #dbe2e9\">RG1 \u2013 Low Risk<\/th>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">With normal behavior, there is no hazard; prolonged direct viewing may require a different evaluation.<\/td>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">Avoid direct viewing through the arrangement of the lighting and consider longer-lasting adjustment work separately.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"padding:12px;text-align:left;border-bottom:1px solid #dbe2e9\">RG2 \u2013 Moderate Risk<\/th>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">The evaluation takes into account, among other things, the limitation of exposure through aversion responses or thermal discomfort.<\/td>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">Limit direct view of the light source, for example, through shields or screening. Define distances, warning notices, and required access restrictions.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"padding:12px;text-align:left;border-bottom:1px solid #dbe2e9\">RG3 \u2013 High Risk<\/th>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">Even a short exposure can be dangerous.<\/td>\n<td style=\"padding:12px;border-bottom:1px solid #dbe2e9\">Make dangerous radiation inaccessible to persons, for example, through a suitable enclosure and, if necessary, a monitored shutdown when opening. Secure service work separately.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The classification is based on the explanations of the <a href=\"https:\/\/publikationen.dguv.de\/widgets\/pdf\/download\/article\/3613\">DGUV on risk groups<\/a>. The measures mentioned are application examples according to <a href=\"https:\/\/www.baua.de\/DE\/Angebote\/Regelwerk\/TROS\/pdf\/TROS-IOS-Teil-3.pdf?__blob=publicationFile&#038;v=1\">TROS IOS, Part 3<\/a>.<\/p>\n<p>For RG2, a safe machine design should not rely solely on persons looking away or closing their eyes in time. Especially during setup and control work, prolonged viewing can occur. Furthermore, the risk group of LED lighting is not to be equated with a laser class.<\/p>\n<h2>What requirements does machine safety impose?<\/h2>\n<p>As of November 2026, the Machinery Directive 2006\/42\/EC is still generally applicable for machines. Its Annex I, Section 1.5.10, requires that harmful radiation exposure be avoided. This also applies to functional non-ionizing radiation during the adjustment, operation, and cleaning of a machine.<\/p>\n<p>For integrated lighting, this means: The machine manufacturer must assess which radiation can actually reach persons and include necessary protective measures in the design. A warning sticker alone does not replace a necessary technical protective measure. <a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/DE\/TXT\/?uri=CELEX%3A02006L0042-20090807\">Machinery Directive 2006\/42\/EC, Annex I<\/a><\/p>\n<p>From <strong>January 20, 2027<\/strong>, the Machinery Directive will be replaced by the <strong>Regulation (EU) 2023\/1230 on machinery<\/strong>. The basic requirement for limiting dangerous radiation remains in Annex III, Section 1.5.10. Safe integration of the lighting is therefore also required under the new legal framework. <a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1230\">EU Machinery Regulation \u2013 consolidated version<\/a><\/p>\n<h2>Technical protection takes precedence<\/h2>\n<p>For workplaces, the Occupational Health and Safety Ordinance on Artificial Optical Radiation (OStrV) specifies the requirements for the protection of employees. Hazards should be avoided or reduced at the source if possible. Technical protective measures take precedence over organizational measures and personal protective equipment.<\/p>\n<p>For an image processing system, the following solutions, for example, come into consideration:<\/p>\n<ul>\n<li>Position lighting so that employees do not look directly into the light source.<\/li>\n<li>Use shielding and baffles against direct and reflected radiation.<\/li>\n<li>Provide a suitable enclosure with necessary interlocking or shutdown functions.<\/li>\n<li>Mark accessible areas and restrict access if necessary.<\/li>\n<li>Use suitable personal protective equipment if technical and organizational measures are not sufficient.<\/li>\n<\/ul>\n<p>The effectiveness of the measures must match the actual hazard. <a href=\"https:\/\/www.gesetze-im-internet.de\/ostrv\/__7.html\">OStrV \u00a7 7 \u2013 Protective measures<\/a><\/p>\n<h2>Special features for UV, infrared, and strobe operation<\/h2>\n<p>With UV and infrared lighting, visible brightness is missing as a warning signal. A seemingly dark light source can therefore still cause relevant radiation exposure. Protective panes and filters must be suitable for the respective wavelength range; a purely optically dark cover is not sufficient proof of the protective effect. <a href=\"https:\/\/www.lia.nrw.de\/themengebiete\/Arbeitsschutz\/physikalische_einwirkungen\/Optische_Strahlung\/index.html\">Optical Radiation \u2013 LIA NRW<\/a>, <a href=\"https:\/\/www.baua.de\/DE\/Angebote\/Regelwerk\/TROS\/pdf\/TROS-IOS-Teil-3.pdf?__blob=publicationFile&#038;v=1\">Technical Protective Measures \u2013 TROS IOS<\/a><\/p>\n<p>Strobe operation is also not automatically eye-safe. In addition to the average radiation, the properties of the individual pulses and the pulse sequence must be taken into account. A short pulse duration or a low <strong>duty cycle<\/strong> alone therefore does not prove safe exposure. An evaluation documented for continuous operation must not be transferred to operation with increased pulse current without verification. <a href=\"https:\/\/www.baua.de\/DE\/Angebote\/Publikationen\/Berichte\/F2377.pdf?__blob=publicationFile&#038;v=4\">Pulsed Incoherent Optical Radiation \u2013 BAuA<\/a><\/p>\n<h2>The specific installation situation is decisive<\/h2>\n<p>For the assessment, in addition to the product specifications, the accessible viewing positions, distances, exposure times, and possible reflections must be taken into account in particular. Multiple light sources operated simultaneously as well as setup, maintenance, and repair work also belong in the assessment.<\/p>\n<p>The risk group specification of a lighting unit supports this assessment but replaces neither the risk assessment of the machine nor the hazard assessment of the workplace. If the actual exposures cannot be safely assessed based on the available information, suitable calculations or measurements are required. <a href=\"https:\/\/www.gesetze-im-internet.de\/ostrv\/__3.html\">OStrV \u00a7 3 \u2013 Hazard assessment<\/a><\/p>\n<p><em>Legal status: November 2026.<\/em><\/p>\n<p>B\u00fcchner Lichtsysteme offers eye safety assessments according to DIN EN 62471.<\/p>\n<\/p>\n<h3>Similar entries<\/h3>\n<ul class=\"related-items\">\n<li class=\"item\"><a href=\"https:\/\/beleuchtung.vision\/en\/wiki-led\/blue-light-hazard\/\" title=\"Blue Light Hazard (BLH) refers to a hazard to the retina caused by radiation in the range of approx. 410 to 480 nm (half-width) with a maximum sensitivity at 440 nm. This high-energy blue light can cause so-called photoretinitis, a photochemical damage to the retina caused by degeneration of the macula (AMD; damage to the retinal...\" class=\"encyclopedia\">Blue Light Hazard<\/a><\/li>\n<li class=\"item\"><a href=\"https:\/\/beleuchtung.vision\/en\/wiki-led\/shock-and-vibration-resistance\/\" title=\"Shock and vibration resistance (impact resistance) provides information about the robustness of the mechanical design of a device. The methods for evaluating shock resistance are defined in IEC 60068-2-27. Shock resistance is important for the operating and transport conditions of the devices. The methods for evaluating vibration resistance are defined in IEC 60068-2-6 and IEC 60068-2-64.\" class=\"encyclopedia\">Shock and Vibration Resistance<\/a><\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A hazard to the eye from LEDs, lamps, or other light sources is defined by DIN EN 62471, 2009-03 edition (Photobiological safety of lamps and lamp systems; German version EN 62471:2008; IEC 62471:2006) &#8230;<\/p>\n","protected":false},"featured_media":0,"template":"","class_list":["post-1532","br_wikiled","type-br_wikiled","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/br_wikiled\/1532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/br_wikiled"}],"about":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/types\/br_wikiled"}],"version-history":[{"count":0,"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/br_wikiled\/1532\/revisions"}],"wp:attachment":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/media?parent=1532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}