{"id":1550,"date":"2026-11-16T22:07:50","date_gmt":"2026-11-16T21:07:50","guid":{"rendered":"https:\/\/beleuchtung.vision\/wiki-led\/protection-class\/"},"modified":"2026-11-21T09:03:43","modified_gmt":"2026-11-21T08:03:43","slug":"protection-class","status":"publish","type":"br_wikiled","link":"https:\/\/beleuchtung.vision\/en\/wiki-led\/protection-class\/","title":{"rendered":"Protection Class"},"content":{"rendered":"<p>IEC\/EN 61140 classifies electrical equipment with regard to safety against dangerous body currents and electric shock. The design features of devices are assigned to the following protection classes:<br \/>\u2013 Protection Class 0: No protection. Such devices are not permitted in the European Union.<br \/>\u2013 Protection Class I: Device with a protective earth connection and basic insulation between accessible parts and the protective earth. A correct protective earth connection is mandatory.<br \/>\u2013 Protection Class II: Device with double or reinforced insulation between accessible parts and parts dangerous to touch. There is no connection option for a protective earth on these devices.<br \/>\u2013 Protection Class III: Device supplied by <a href=\"https:\/\/beleuchtung.vision\/en\/wiki-led\/selv\/\">SELV<\/a> or <a href=\"https:\/\/beleuchtung.vision\/en\/wiki-led\/pelv\/\">PELV<\/a> circuits and in which no higher voltages are generated than are permitted for <a href=\"https:\/\/beleuchtung.vision\/en\/wiki-led\/selv\/\" target=\"_self\" title=\"SELV (Safety Extra Low Voltage) describes a voltage selected to be so low that there is no danger from excessive body currents in the event of direct contact, both during intended operation and in the event of a single fault. If insulation fails, sufficient protection must still be provided. For power supply units...\" class=\"encyclopedia\">SELV<\/a> or <a href=\"https:\/\/beleuchtung.vision\/en\/wiki-led\/pelv\/\" target=\"_self\" title=\"PELV (Protective Extra Low Voltage; see also SELV) describes a voltage selected to be so low (extra-low voltage) that there is no danger from body currents in the event of indirect contact or non-extensive direct contact. If insulation fails, sufficient protection must still be provided. For power supply units, this is achieved by...\" class=\"encyclopedia\">PELV<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>IEC\/EN 61140 classifies electrical equipment with regard to safety against dangerous body currents and electric shock. The design features of devices are assigned to the following protection classes: \u2013 Protection Class &#8230;<\/p>\n","protected":false},"featured_media":0,"template":"","class_list":["post-1550","br_wikiled","type-br_wikiled","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/br_wikiled\/1550","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/br_wikiled"}],"about":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/types\/br_wikiled"}],"version-history":[{"count":0,"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/br_wikiled\/1550\/revisions"}],"wp:attachment":[{"href":"https:\/\/beleuchtung.vision\/en\/wp-json\/wp\/v2\/media?parent=1550"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}