The service life of LED lighting depends on the LED technology used, the electrical load, and the operating thermal conditions. Reliable classification therefore always requires reference to the specific model and its operating conditions.
This article explains these relationships based on the Büchner Technical Information document “Service Life of LED Lights,” Version 1.0. The hour ratings specified therein are reproduced below as reference values for this document version.
What Does Service Life Mean for LED Lighting?
LEDs do not necessarily fail abruptly to reach the end of a specified service life. What is often decisive is the gradual decrease in their intensity.
In Technical Information V1.0, the service life is defined as the point in time at which intensity has dropped to 50% of the original intensity. The document notes that in individual cases, specifications may also refer to other reference thresholds, such as 75%. Service life values can therefore only be meaningfully compared if both the underlying intensity threshold and the operating conditions are known.
Which Factors Influence Service Life?
- LED Design and Component Selection: The characteristics of the LED technology used and the individual components influence aging behavior.
- Thermal Load: Heat dissipation, mounting, and the thermal conditions within the system affect the stress placed on the LEDs.
- Current Load: Electrical stress during operation is a key influencing factor alongside temperature.
- Individual Variance: Even LEDs of the same type can differ in their aging behavior. Hour figures should therefore be regarded as reference values.
Reference Values from Technical Information V1.0
The following values are taken from the specified document version. They do not constitute a binding service life guarantee for a specific current product version. In particular, they do not replace an evaluation of the actual current and thermal loads.
| Light Color / Range | Documented Reference Value |
|---|---|
| Red and Infrared | approx. 50,000–100,000 h and more |
| White and Green | approx. 10,000–20,000 h and more |
| UV | a few thousand hours |
The document does not provide a dedicated hour value for blue LEDs. Therefore, no value for blue is derived from the other specifications. Furthermore, the advancement of LED technology described in the document does not serve as blanket proof of a specific service life for today’s products.
Designing Durable Lighting
The Technical Information cites high-quality LEDs and appropriate binning selections, optimized heat dissipation, and minimal thermal load as fundamental design principles. It also describes operating LEDs at a reduced current relative to the manufacturer’s nominal ratings as a measure to enhance service life and reliability. For the operation of any specific illumination system, its certified electrical and thermal limits apply.
What Can Be Optimized During Operation?
- Dissipate Heat: Mount the lighting with thermal conductivity wherever possible.
- Enable Convection: Avoid obstructing ventilation and air circulation in the system as much as possible.
- Maintain Electrical Limits: Avoid excessive operating voltage and observe the specifications for the respective model.
- Reduce Unnecessary Operating Time: Switch off suitable lighting during operating pauses and between image acquisitions.
Switched Operation and Duty Cycle
Because LEDs can be switched very quickly, they are ideal for targeted operation during required image acquisition. The Technical Information describes turning off the light during pauses as an effective way to extend the achievable service life. It highlights this particularly for green, blue, and white LEDs, as well as for UV LEDs.
The extent of improvement depends on the operating conditions. The document does not specify a universally applicable conversion factor. Consequently, it does not support calculating service life solely based on the duty cycle, nor does it provide authorization for overdriven strobe operation with increased current.
Service Life of Devices and Electronics
For complete devices and electronic assemblies, components other than LEDs must also be considered. Signs of wear can occur, for example, in capacitors. Device design, component quality, the placement of temperature-sensitive parts, unobstructed airflow, and effective heat dissipation all influence the service life.
An example of a conditional device service life specification is 50,000 h at rated output current, +40 °C ambient temperature, and rated input voltage. Such a specification must only be used in conjunction with the respective device specification; it does not represent a general minimum value for all LED lighting systems.
Service life hours must not be confused with MTBF specifications. The decrease in light intensity, the service life of an entire electronic assembly, and statistical reliability metrics describe fundamentally different parameters.
Source and Further Information
Basis for the LED section: Technical Information “Service Life of LED Lights,” Version 1.0 – Open original PDF. Subject to technical changes.
To evaluate a specific lighting system, its model and actual operating conditions must be taken into account. Discuss questions regarding suitable design and operation.