ARCUS-190

Dunkelfeldbeleuchtungen

ARCUS-190

  • Außen-/Innendurchmesser: 240/190mm
  • 2 LED-Reihen
  • Optional 2 oder 4 getrennt ansteuerbare Kanäle
  • optional mit Schalteingang (3,7-24V)

Variants:

Inquire about product →Datasheet as PDF →

Specifications

Technical Specifications

01

General technical and commercial data

Design & Mechanics

Outer/inner diameter
240/190mm
Housing
Aluminum black anodized
Front / Cover
PMMA
Weight
approx. 688 g
LEDs
240

Operation & Connection

Electrical versions and connections
  • 24 VDC · 1-channelM8 Connector 4-pin
  • 24 VDC with switching input · 1-channelM8 Connector 4-pin
  • SC · 1-channelM8 Connector 4-pin
  • 24 VDC · 2-channelM8 Connector 4-pin
  • SC · 2-channelM8 Connector 4-pin
  • 24 VDC · 4-channelM8 Connector 6-pin
  • SC · 4-channelM8 Connector 6-pin
Ambient Temperature
max. 50 °C recommended
Protection class (IP)
IP40
electrical protection class
III, safety extra-low voltage operation
Compliance
CE, RoHS
service life
The service life of LED lighting depends on many factors.
Service life explained in WikiLED →
02

Model-dependent characteristics

Model-dependent characteristics

In narrow view, the table can be shifted sideways.

variantCurrent and flash operationMeasured values and classification
Light colourWavelength / Color Temperaturenm / KBeam angleLED · °ChannelsCurrent consumption24VDC type / max. Konstantstrom SC-TypApproximate valuesMax. pulse current24VDC type / SC-Typ
t < 1 ms
Duty Cycle 1:10
Depending on flash conditions
IrradianceW/m² at constant current
@ 0,01 m
Approximate values · Distance from bottom edge of housing
Electrical powerWRisk groupEN 62471
Red615 nm120°11.020 mA2.400 mA53 W/m²25 Wexempt group
white5.800 K120°1930 mA6.200 mA27 W/m²23 Wexempt group
Infrared850 nm120°–––––exempt group
Blue470 nm120°1950 mA6.200 mA39 W/m²23 W1
Green525 nm120°–––––exempt group
Red633 nm–––––––
Red615 nm120°2510 mA / Kanal1200 mA / Kanal53 W/m²25 Wexempt group
white5.800 K120°2465 mA / Kanal3100 mA / Kanal27 W/m²23 Wexempt group
white5.800 K120°4232,5 mA / Kanal1550 mA / Kanal27 W/m²23 Wexempt group
Blue470 nm120°2475 mA / Kanal3100 mA / Kanal39 W/m²23 W1
Blue470 nm120°4237,5 mA / Kanal1550 mA / Kanal39 W/m²23 W1

Notes on the specifications table

Additional light colors and versions from UV to infrared available upon request.

03

Connection and PIN assignment

M8 Connector 4-pin · 24VDC · 1-channel

Connector drawing
PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-

M8 Connector 4-pin · 24VDC with switching input · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-
4blackblackSwitching input*

* ON: 3,7V (3mA) - 24V (30mA) / OFF: < 2,5V

M8 Connector 4-pin · SC · 1-channel

Connector drawing
PINFarbeWire colorFunction
4blackblack+
3blueblue-
04

Dimensional drawing

Dimensional drawing ARCUS-190
05

Operating instructions

Areas of application

This version is designed for continuous operation at 24VDC.

Operating modes

  • DC operation on a suitable power supply with 24VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay
  • switched operation on a lighting controller (e.g. IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • brightness-controlled operation via lighting controller (IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply

Flash operation

Flash operation via controller (e.g., IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply. Depending on the lighting controller used and the maximum available output/flash voltage, the flash current in this combination can be increased by a maximum factor of 2 to 3 in order to remain within the permitted voltage range of the output/flash voltage of max. 50V.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

Areas of application

This version is designed for switching and continuous operation at 24 VDC and has an additional switching input.

Control

A suitable external control signal, such as from a camera, PLC, or similar device, allows the illumination to be selectively switched on and off while power is supplied.

Flash operation

The variant is not suitable for flash operation with excessive currents.

Areas of application

This low-resistance version, optimized for flash operation, can also be used for switched, brightness-controlled, and continuous operation.

Required supply

One of the following power supplies is required for operation:

  • a lighting controller, e.g. from the IPSC/HPSC series, from Gefasoft or Gardasoft, or
  • a current source with current limiting.

Flash operation

Due to its low-resistance design, the SC version is particularly suitable for maximum current in flash operation. Compared to the 24-VDC types, output or flash voltages in the usual range up to a maximum of 50 V can be used.

As a result, the maximum flash current is typically significantly above the factor 2–3.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

06

Application, light guidance, and optics

Application and light guidance

Application and light guidance – ARCUS-190

Product inquiry

ARCUS-190 check for your application

Briefly describe your Prüfaufgabe.

Product: ARCUS-190

PDF Datasheet · Version 4.0

Select datasheet

ARCUS-190

Scope of the Data Sheet

The datasheet opens in a new tab. You can save it there as a PDF.