TOP-LINE-Serie

Dunkelfeldbeleuchtungen

TOP-LINE-Serie

  • Innendurchmesser: ab ca. 129/185/241mm
  • vielseitig, modular und einstellbar
  • jedes Modul kann einzeln angesteuert werden
  • kippbare Halterung erhältlich
Inquire about product →Datasheet as PDF →

Specifications

Technical Specifications

01

General technical and commercial data

Design & Mechanics

Inner diameter
from approx. 129/185/241mm
Housing
Aluminum, black or natural anodized
Weight
2HP: approx. 105 g; 3HP: approx. 160 g; 4HP: approx. 190 g
LEDs
2HP: 16; 3HP: 24; 4HP: 32

Operation & Connection

Ambient Temperature
max. 50 °C recommended
Protection class (IP)
depending on version
Connection
M8 connector (4-pin)**
Versorgung
24 VDC type or 12 VDC type: 24 VDC or 12 VDC SC-Typ: For use with a controller
service life
The service life of the LEDs in our lights is very high, but depends on many different factors such as ambient temperature, current load, etc.
Service life explained in WikiLED →
02

Model-dependent characteristics

Please verify that this information is up to date before use.

Model-dependent characteristics

In narrow view, the table can be shifted sideways.

variantCurrent and flash operationMeasured values and classification
Light colourWavelength / Color Temperaturenm / KBeam angleLED · °variantCurrent consumption24VDC type / max. Konstantstrom SC-Typ24 VDC · approximate valuesMax. pulse current24VDC type / SC-Typ
t < 1 ms
Duty Cycle 1:10
Depending on flash conditions
IrradianceW/m² at constant current
@ 0,1 m
Approximate values
Electrical powerW
Red617 nm30°2TE70 mA200 mA25 W/m²2 W
Red617 nm30°3TE105 mA300 mA28 W/m²3 W
Red617 nm30°4TE140 mA400 mA31 W/m²4 W
Red617 nm60°2TE70 mA200 mA–2 W
Red617 nm60°3TE105 mA300 mA–3 W
Red617 nm60°4TE140 mA400 mA25 W/m²4 W
Red635 nm120°2TE50 mA200 mA–2 W
Red635 nm120°3TE75 mA300 mA–2 W
Red635 nm120°4TE100 mA400 mA–3 W
Infrared850 nm30°2TE65 mA800 mA22 W/m²2 W
Infrared850 nm30°3TE95 mA1200 mA–3 W
Infrared850 nm30°4TE130 mA1600 mA–4 W
Infrared850 nm50°2TE65 mA800 mA–2 W
Infrared850 nm50°3TE95 mA1200 mA20 W/m²3 W
Infrared850 nm50°4TE130 mA1600 mA–4 W
Infrared850 nm120°2TE–800 mA––
Infrared850 nm120°3TE–1200 mA––
Infrared850 nm120°4TE–1600 mA––
Blue470 nm20°2TE85 mA320 mA5 W/m²3 W
Blue470 nm20°3TE125 mA480 mA5 W/m²3 W
Blue470 nm20°4TE170 mA640 mA5 W/m²5 W
UV375 nm120°2TE80 mA–7 W/m²2 W
UV375 nm120°3TE110 mA–7 W/m²3 W
UV375 nm120°4TE140 mA–7 W/m²4 W

Notes on the specifications table

Additional light colors and versions from UV to infrared available upon request.

Safety note: LED light systems can generate very intense radiation that can damage the eyes if used improperly. Do not look directly into the light beams with unprotected eyes; use suitable eye protection if necessary.

03

Connection and PIN assignment

M8 Connector 4-pin · 24VDC · 1-channel

Connector drawing
PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-

M8 Connector 4-pin · 12VDC · 1-channel

1-kanalig · 12VDC · 1-kanalig · M8 Stecker 4-polig

Connector drawing

Front view of housing

PINFarbeWire colorFunction
2whitewhite+ 12V
3blueblue-

M8 Connector 4-pin · SC · 1-channel

Connector drawing
PINFarbeWire colorFunction
4blackblack+
3blueblue-
04

Dimensional drawing

Dimensional drawing TOP-LINE-Serie
Source: Archive data sheet.
05

Operating instructions

Depending on the version, the lights are designed for continuous operation at 24VDC or 12VDC. The following operating modes are possible:

  • DC operation on a suitable power supply with 24VDC or 12VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay or controller (GS or SC series)
  • brightness-controlled operation via controller (GS or SC series) in conjunction with a suitable power supply
  • Flash operation via controller (GS or SC series) in conjunction with a suitable power supply. The LED current can be increased by a maximum factor of 2 to 3 in flash operation.

For flash, switched, or brightness-controlled operation, the lights are optionally available as an optimized SC version. They can be used in combination with our GS or SC series controllers and enable optimized or maximum current, especially in pulse mode. We would be happy to advise you on the selection of suitable components.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

Safety note! Can cause damage. Do not look directly into the light beams with unprotected eyes! Use eye protection if necessary!

06

Application, light guidance, and optics

Application and light guidance

Application and light guidance – TOP-LINE-Serie

Product inquiry

TOP-LINE-Serie check for your application

Briefly describe your Prüfaufgabe.

Product: TOP-LINE-Serie

PDF Datasheet · Version 4.0

Select datasheet

TOP-LINE-Serie

Scope of the Data Sheet

The datasheet opens in a new tab. You can save it there as a PDF.