HI-LINE-D1

Hintergrundbeleuchtungen

HI-LINE-D3

  • Gehäusemaß: ca. 190x25x23 mm³
  • Aktive Fläche: ca. 168x15 mm²
  • integrierter Kühlkörper
  • linienförmiges Durchlicht

Variants:

Inquire about product →Datasheet as PDF →

Specifications

Technical Specifications

01

General technical and commercial data

Design & Mechanics

Housing dimensions
approx. 190x25x23 mm³
Aktive Fläche
approx. 168x15 mm²
Housing
Aluminum blasted natural anodized
Front / Cover
PMMA
Weight
approx. 190 g
LEDs
48 /30 (RGB)

Operation & Connection

Electrical versions and connections
  • 24 VDC · 1-channelM8 Connector 4-pin
  • SC · 1-channelM8 Connector 4-pin
  • 24 VDC · 1-channelM8 Connector 6-pin
  • SC · 1-channelM8 Connector 6-pin
Ambient Temperature
max. 50 °C recommended
Protection class (IP)
IP50
electrical protection class
III, safety extra-low voltage operation
Compliance
CE, RoHS
service life
The service life of LEDs is in the range of several 10.000 to 100.000 hours and is generally very high, but depends on many different factors such as ambient temperature, current load, etc.
Service life explained in WikiLED →
02

Model-dependent characteristics

Model-dependent characteristics

In narrow view, the table can be shifted sideways.

variantCurrent and flash operationMeasured values and classification
Light colourWavelength / Color Temperaturenm / KBeam angleLED · °variantChannelsMax. pulse current24VDC type / SC-Typ
t < 1 ms
Duty Cycle 1:10
Depending on flash conditions
Risk groupEN 62471
Red635 nm120°–1600 mAexempt group
White5.200 K120°–1600 mAexempt group
Infrared850 nm30°–––exempt group
Infrared850 nm50°–––exempt group
Infrared850 nm120°––2400 mA–
Blue470 nm120°–1900 mA–
Red630 nm120°RGB–––
Green530 nm120°RGB––exempt group
Blue470 nm120°RGB1–exempt group
Green525 nm–––––

Notes on the specifications table

Current consumption applies to the 24-VDC version, maximum constant current for the SC version.

The specified current values are approximate values.

The intensity specifications are approximate values in continuous operation (DC).

Measuring distance: 200 mm below the bottom edge of the housing.

Additional light colors and versions from UV to infrared available upon request.

03

Connection and PIN assignment

M8 Connector 4-pin · 24VDC · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue- (Kanal 1 / Channel 1)

Exclusively einkanalig Ausführung: PIN 1 is +24V, PIN 3 is minus (channel 1). The connection to PIN 4 shown in parentheses in the original is not part of this Anschlussbelegung. Its German and English channel numbers contradict each other; technical clarification is still required for mehrkanalig use.

M8 Connector 4-pin · SC · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
4blackblack+
3blueblue- (Kanal 1 / Channel 1)

Single-channel version: PIN 4 is positive, PIN 3 is negative (channel 1). The optional second channel at PIN 2 shown in brackets in the original does not belong to this single-channel assignment. The separate two-channel profile applies to the two-channel version.

04

Dimensional drawing

Dimensional drawing HI-LINE-D3
05

Operating instructions

Areas of application

This version is designed for continuous operation at 24VDC.

Operating modes

  • DC operation on a suitable power supply with 24VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay
  • switched operation on a lighting controller (e.g. IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • brightness-controlled operation via lighting controller (IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply

Flash operation

Flash operation via controller (e.g., IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply. Depending on the lighting controller used and the maximum available output/flash voltage, the flash current in this combination can be increased by a maximum factor of 2 to 3 in order to remain within the permitted voltage range of the output/flash voltage of max. 50V.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

Areas of application

This low-resistance version, optimized for flash operation, can also be used for switched, brightness-controlled, and continuous operation.

Required supply

One of the following power supplies is required for operation:

  • a lighting controller, e.g. from the IPSC/HPSC series, from Gefasoft or Gardasoft, or
  • a current source with current limiting.

Flash operation

Due to its low-resistance design, the SC version is particularly suitable for maximum current in flash operation. Compared to the 24-VDC types, output or flash voltages in the usual range up to a maximum of 50 V can be used.

As a result, the maximum flash current is typically significantly above the factor 2–3.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

06

Application, light guidance, and optics

Technical Notes

Technical Notes – HI-LINE-D3

Ausführungen and Segmentsteuerung

Ausführungen and Segmentsteuerung – HI-LINE-D3

Application and light guidance

Application and light guidance – HI-LINE-D3

Product inquiry

HI-LINE-D3 check for your application

Briefly describe your Prüfaufgabe.

Product: HI-LINE-D3

PDF Datasheet · Version 4.0

Select datasheet

HI-LINE-D3

Scope of the Data Sheet

The datasheet opens in a new tab. You can save it there as a PDF.