  • Gehäusemaß: 74x17x15 mm
  • klein, kompakt, vielseitig
  • optional mit Zylinderlinse erhältlich
  • unterschiedliche Fronten/Diffusoren erhältlich

Variants:

Inquire about product →Datasheet as PDF →

Specifications

Technical Specifications

01

General technical and commercial data

Design & Mechanics

Housing dimensions
74x17x15 mm
Housing
Aluminum blasted natural anodized
Front / Cover
PMMA
Weight
approx. 30 g
LEDs
8

Operation & Connection

Electrical versions and connections
  • 24 VDC · 1-channelM8 Connector 4-pin
  • SCM8 Connector 4-pin
Ambient Temperature
max. 50 °C recommended
Protection class (IP)
IP50
electrical protection class
III, safety extra-low voltage operation
Compliance
CE, RoHS
service life
The service life of LED lighting depends on many factors.
Service life explained in WikiLED →
02

Model-dependent characteristics

Model-dependent characteristics

In narrow view, the table can be shifted sideways.

variantCurrent and flash operationMeasured values and classification
Light colourWavelength / Color Temperaturenm / KBeam angleLED · °ChannelsCurrent consumption24VDC type / max. Konstantstrom SC-TypApproximate values · Values per single-channel LOGO-2 base moduleMax. pulse current24VDC type / SC-Typ
t < 1 ms
Duty Cycle 1:10
Depending on flash conditions · Values per einkanalig LOGO-2 base module
IrradianceW/m² at constant current
@ 0,2 m
Approximate values · Distance from bottom edge of housing · Values per single-channel LOGO-2 base module
Electrical powerWValues per single-channel LOGO-2 base moduleRisk groupEN 62471
Red635 nm120°130 mA100 mA5 W/m²1 Wexempt group
Red617 nm60°140 mA100 mA14 W/m²1 Wexempt group
Red617 nm30°140 mA200 mA24 W/m²1 Wexempt group
White5.200 K120°135 mA100 mA5,5 W/m²1 Wexempt group
Infrared850 nm120°145 mA400 mA4,8 W/m²2 Wexempt group
Infrared850 nm50°135 mA–5,9 W/m²1 Wexempt group
Infrared850 nm30°135 mA400 mA26 W/m²1 Wexempt group
Blue470 nm120°160 mA260 mA5 W/m²2 Wexempt group
Blue470 nm30°145 mA150 mA23 W/m²2 WRg2
Green525 nm120°160 mA130 mA2,4 W/m²2 Wexempt group
Green525 nm30°145 mA100 mA3,1 W/m²2 Wexempt group
UV375 nm120°135 mA160 mA3,3 W/m²1 W–
UV365 nm120°1––––Rg1

Notes on the specifications table

Additional light colors and versions from UV to infrared available upon request.

No total values are specified for combination or tunnel.

03

Connection and PIN assignment

M8 Connector 4-pin · 24VDC · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue- (Kanal 1 / Channel 1)

Exclusively einkanalig Ausführung: PIN 1 is +24V, PIN 3 is minus (channel 1). The connection to PIN 4 shown in parentheses in the original is not part of this Anschlussbelegung. Its German and English channel numbers contradict each other; technical clarification is still required for mehrkanalig use.

04

Dimensional drawing

Dimensional drawing LOGO-2
05

Operating instructions

Areas of application

This version is designed for continuous operation at 24VDC.

Operating modes

  • DC operation on a suitable power supply with 24VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay
  • switched operation on a lighting controller (e.g. IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • brightness-controlled operation via lighting controller (IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply

Flash operation

Flash operation via controller (e.g., IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply. Depending on the lighting controller used and the maximum available output/flash voltage, the flash current in this combination can be increased by a maximum factor of 2 to 3 in order to remain within the permitted voltage range of the output/flash voltage of max. 50V.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

Areas of application

This low-resistance version, optimized for flash operation, can also be used for switched, brightness-controlled, and continuous operation.

Required supply

One of the following power supplies is required for operation:

  • a lighting controller, e.g. from the IPSC/HPSC series, from Gefasoft or Gardasoft, or
  • a current source with current limiting.

Flash operation

Due to its low-resistance design, the SC version is particularly suitable for maximum current in flash operation. Compared to the 24-VDC types, output or flash voltages in the usual range up to a maximum of 50 V can be used.

As a result, the maximum flash current is typically significantly above the factor 2–3.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

06

Application, light guidance, and optics

Technical Notes

Technical Notes – LOGO-2

Application and light guidance

Application and light guidance – LOGO-2

Product inquiry

LOGO-2 check for your application

Briefly describe your Prüfaufgabe.

Product: LOGO-2

PDF Datasheet · Version 4.0

Select datasheet

LOGO-2

Scope of the Data Sheet

The datasheet opens in a new tab. You can save it there as a PDF.