TOP-LIGHT-40/120

Flächenbeleuchtungen Auflicht

TOP-LIGHT-40/120

  • Gehäusemaß: 47 x 127 x 21 mm
  • thermisch optimiertes Alu-Gehäuse
  • optional mit Schalteingang (3,7-24V)
  • unterschiedliche Fronten/Diffusoren erhältlich

Variants:

Inquire about product →Datasheet as PDF →

Specifications

Technical Specifications

01

General technical and commercial data

Design & Mechanics

Housing dimensions
47 x 127 x 21 mm
Housing
Milled aluminum, matte bead-blasted, silver anodized
Diffuser
PMMA
Weight
approx. 155 g
LEDs
48 / 75 (RGB)

Operation & Connection

Electrical versions and connections
  • 24 VDC · 1-channelM8 Connector 4-pin
  • 24 VDC with switching input · 1-channelM8 Connector 4-pin
  • SC · 1-channelM8 Connector 4-pin
  • 24 VDC · 3-channelM8 Connector 6-pin
  • SC · 3-channelM8 Connector 6-pin
Ambient Temperature
max. 50 °C recommended
Protection class (IP)
IP50
electrical protection class
III, safety extra-low voltage operation
Compliance
CE, RoHS
service life
The service life of LED lighting depends on many factors.
Service life explained in WikiLED →
02

Model-dependent characteristics

Model-dependent characteristics

In narrow view, the table can be shifted sideways.

variantCurrent and flash operationMeasured values and classification
Light colourWavelength / Color Temperaturenm / KBeam angleLED · °Current consumption24VDC type / max. Konstantstrom SC-TypApproximate valuesMax. pulse current24VDC type / SC-Typ
t < 1 ms
Duty Cycle 1:10
Depending on flash conditions
IrradianceW/m² at constant current
@ 0,2 m
Approximate values · Distance from bottom edge of housing
Electrical powerWRisk groupEN 62471
Red635 nm120°––––exempt group
Red617 nm60°––––exempt group
Red617 nm30°220 mA600 mA10 W/m²6 Wexempt group
White5.200 K120°160 mA–8 W/m²4 Wexempt group
Infrared850 nm120°200 mA–13 W/m²5 Wexempt group
Infrared850 nm50°––––exempt group
Infrared850 nm30°215 mA2400 mA52 W/m²6 Wexempt group
Blue470 nm120°––––exempt group
Blue470 nm30°––––exempt group
Green525 nm120°––––exempt group
Green525 nm30°––––exempt group
RGB – Red635 nm120°130 mA je Lichtfarbe; max. 390 mA gesamt9000 mA pro Farbe4 W/m²10 W gesamt (max.); 4 W je Lichtfarbeexempt group
RGB – Green520 nm120°130 mA je Lichtfarbe; max. 390 mA gesamt9000 mA pro Farbe3,4 W/m²10 W gesamt (max.); 4 W je Lichtfarbeexempt group
RGB – Blue470 nm120°130 mA je Lichtfarbe; max. 390 mA gesamt9000 mA pro Farbe7,6 W/m²10 W gesamt (max.); 4 W je Lichtfarbeexempt group

Notes on the specifications table

Additional light colors and versions from UV to infrared available upon request.

03

Connection and PIN assignment

M8 Connector 4-pin · 24VDC · 1-channel

Connector drawing
PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-

M8 Connector 4-pin · 24VDC with switching input · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-
4blackblackSwitching input*

* ON: 3,7V (3mA) - 24V (30mA) / OFF: < 2,5V

M8 Connector 4-pin · SC · 1-channel

Connector drawing
PINFarbeWire colorFunction
4blackblack+
3blueblue-

M8 connector 6-pin · 24VDC · 3-channel · RGB · common positive pole

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue- Blau / - Blue
5greygrey- Grün / - Green
6pinkpink- Rot / - Red

M8 connector 6-pin · SC · 3-channel · RGB · common positive pole

Connector drawing

Front view of housing

PINFarbeWire colorFunction
4blackblack+
3blueblue- Blau / - Blue
5greygrey- Grün / - Green
6pinkpink- Rot / - Red
04

Dimensional drawing

Dimensional drawing TOP-LIGHT-40/120
05

Operating instructions

Areas of application

This version is designed for continuous operation at 24VDC.

Operating modes

  • DC operation on a suitable power supply with 24VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay
  • switched operation on a lighting controller (e.g. IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • brightness-controlled operation via lighting controller (IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply

Flash operation

Flash operation via controller (e.g., IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply. Depending on the lighting controller used and the maximum available output/flash voltage, the flash current in this combination can be increased by a maximum factor of 2 to 3 in order to remain within the permitted voltage range of the output/flash voltage of max. 50V.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

Areas of application

This version is designed for switching and continuous operation at 24 VDC and has an additional switching input.

Control

A suitable external control signal, such as from a camera, PLC, or similar device, allows the illumination to be selectively switched on and off while power is supplied.

Flash operation

The variant is not suitable for flash operation with excessive currents.

Areas of application

This low-resistance version, optimized for flash operation, can also be used for switched, brightness-controlled, and continuous operation.

Required supply

One of the following power supplies is required for operation:

  • a lighting controller, e.g. from the IPSC/HPSC series, from Gefasoft or Gardasoft, or
  • a current source with current limiting.

Flash operation

Due to its low-resistance design, the SC version is particularly suitable for maximum current in flash operation. Compared to the 24-VDC types, output or flash voltages in the usual range up to a maximum of 50 V can be used.

As a result, the maximum flash current is typically significantly above the factor 2–3.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

06

Application, light guidance, and optics

Technical Notes

Technical Notes – TOP-LIGHT-40/120

Application and light guidance

Application and light guidance – TOP-LIGHT-40/120

Product inquiry

TOP-LIGHT-40/120 check for your application

Briefly describe your Prüfaufgabe.

Product: TOP-LIGHT-40/120

PDF Datasheet · Version 4.0

Select datasheet

TOP-LIGHT-40/120

Scope of the Data Sheet

The datasheet opens in a new tab. You can save it there as a PDF.