HELIOS-130

Ringbeleuchtungen

HELIOS-130

  • Außen-/Innendurchmesser: ca. 134 / 66 mm
  • Gehäusehöhe: ca. 25 mm
  • Schutzart (IP): IP65
  • 20 High-Power LEDs

Variants:

Inquire about product →Datasheet as PDF →

Specifications

Technical Specifications

01

General technical and commercial data

Design & Mechanics

Outer/inner diameter
approx. 134 / 66 mm
Housing height
approx. 25 mm
Housing
Milled aluminum, silver anodized
Diffuser
PMMA
Weight
approx. 440 g
LEDs
20

Operation & Connection

Electrical versions and connections
  • 24 VDC · 1-channelM8 Connector 4-pin
  • 24 VDC · 1-channelM12 Connector 5-pin
  • 24 VDC with switching input · 1-channelM8 Connector 4-pin
  • 24 VDC with switching input · 1-channelM12 Connector 5-pin
  • SC · 1-channelM8 Connector 4-pin
  • SC · 1-channelM12 Connector 5-pin
  • 24 VDC · 4-kanalig · Polarität +M8 Connector 6-pin
  • 24 VDC · 4-kanalig · Polarität -M8 Connector 6-pin
  • 24 VDC · 4-kanalig · Polarität +M12 Connector 5-pin
  • 24 VDC · 4-kanalig · Polarität -M12 Connector 5-pin
  • SC · 4-channel · Polarity +M8 Connector 6-pin
  • SC · 4-channel · Polarity -M8 Connector 6-pin
  • SC · 4-channel · Polarity +M12 Connector 5-pin
  • SC · 4-channel · Polarity -M12 Connector 5-pin
Protection class (IP)
IP65
Ambient Temperature
max. 50 °C recommended
electrical protection class
III, safety extra-low voltage operation
Compliance
CE, RoHS
service life
The service life of LEDs is in the range of several 10.000 to 100.000 hours and is generally very high, but depends on many different factors such as ambient temperature, current load, etc.
Service life explained in WikiLED →
02

Model-dependent characteristics

Model-dependent characteristics

In narrow view, the table can be shifted sideways.

variantCurrent and flash operationMeasured values and classification
Light colourWavelength / Color Temperaturenm / KBeam angleLED · °ChannelsCurrent consumption24VDC type / max. Konstantstrom SC-TypApproximate valuesMax. pulse current24VDC type / SC-Typ
t < 1 ms
Duty Cycle 1:10
Depending on flash conditions
IrradianceW/m² at constant current
@ 0,15 m
Approximate values
Electrical powerWRisk groupEN 62471
Red625 nm80°1590 mA4 A85 W/m²15 Wexempt group
Red625 nm36°1590 mA4 A–15 Wexempt group
Red625 nm23°1590 mA4 A–15 Wexempt group
Red625 nm16°1590 mA4 A430 W/m²15 Wexempt group
white5.000 K80°1590 mA8 A65 W/m²15 W–
white5.000 K36°1590 mA8 A118 W/m²15 W–
white5.000 K23°1590 mA8 A138 W/m²15 W–
white5.000 K16°1590 mA8 A150 W/m²15 W–
Infrared850 nm36°1590 mA12 A–15 W–
Infrared850 nm16°1590 mA12 A300 W/m²15 W–
Blue470 nm80°1590 mA8 A65 W/m²15 W–
Blue470 nm36°1590 mA8 A–15 W–
Blue470 nm23°1590 mA8 A–15 W–
Blue470 nm16°1590 mA8 A–15 W–
Green525 nm80°1590 mA8 A–15 W–
Green525 nm36°1590 mA8 A–15 W–
Green525 nm23°1590 mA8 A–15 W–
Green525 nm16°1590 mA8 A–15 W–
Red625 nm45°––––––
White5.000 K45°––––––
IR850 nm80°––––––
IR850 nm45°––––––
IR850 nm23°––––––
Blue470 nm45°––––––
Green525 nm45°––––––
UV365 nm30°––––––
UV365 nm60°––––––
UV365 nm120°––––––
UV385 nm30°––––––
UV385 nm60°––––––
UV385 nm120°––––––
UV395 nm30°––––––
UV395 nm60°––––––
UV395 nm120°––––––
Red625 nm80°4147,5 mA / Kanal1 A / Kanal85 W/m²15 Wexempt group
Red625 nm36°4147,5 mA / Kanal1 A / Kanal–15 Wexempt group
Red625 nm23°4147,5 mA / Kanal1 A / Kanal–15 Wexempt group
Red625 nm16°4147,5 mA / Kanal1 A / Kanal430 W/m²15 Wexempt group
white5.000 K80°4147,5 mA / Kanal2 A / Kanal65 W/m²15 W–
white5.000 K36°4147,5 mA / Kanal2 A / Kanal118 W/m²15 W–
white5.000 K23°4147,5 mA / Kanal2 A / Kanal138 W/m²15 W–
white5.000 K16°4147,5 mA / Kanal2 A / Kanal150 W/m²15 W–
Infrared850 nm36°4147,5 mA / Kanal3 A / Kanal–15 W–
Infrared850 nm16°4147,5 mA / Kanal3 A / Kanal300 W/m²15 W–
Blue470 nm80°4147,5 mA / Kanal2 A / Kanal65 W/m²15 W–
Blue470 nm36°4147,5 mA / Kanal2 A / Kanal–15 W–
Blue470 nm23°4147,5 mA / Kanal2 A / Kanal–15 W–
Blue470 nm16°4147,5 mA / Kanal2 A / Kanal–15 W–
Green525 nm80°4147,5 mA / Kanal2 A / Kanal–15 W–
Green525 nm36°4147,5 mA / Kanal2 A / Kanal–15 W–
Green525 nm23°4147,5 mA / Kanal2 A / Kanal–15 W–
Green525 nm16°4147,5 mA / Kanal2 A / Kanal–15 W–

Notes on the specifications table

Additional light colors and versions from UV to infrared available upon request.

03

Connection and PIN assignment

M8 Connector 4-pin · 24VDC · 1-channel

Connector drawing
PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-

M12 Connector 5-pin · 24VDC · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-

M8 Connector 4-pin · 24VDC with switching input · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-
4blackblackSwitching input*

* ON: 3,7V (~3mA) - 24V (~30mA) / OFF: < 3,0V

M12 Connector 5-pin · 24VDC with switching input · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-
4blackblackSwitching input*

* ON: 3,7V (~3mA) - 24V (~30mA) / OFF: < 3,0V

M8 Connector 4-pin · SC · 1-channel

Connector drawing
PINFarbeWire colorFunction
4blackblack+
3blueblue-

M12 Connector 5-pin · SC · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
4blackblack+
3blueblue-
04

Dimensional drawing

Dimensional drawing HELIOS-130
05

Operating instructions

Areas of application

This version is designed for continuous operation at 24VDC.

Operating modes

  • DC operation on a suitable power supply with 24VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay
  • switched operation on a lighting controller (e.g. IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • brightness-controlled operation via lighting controller (IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply

Flash operation

Flash operation via controller (e.g., IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply. Depending on the lighting controller used and the maximum available output/flash voltage, the flash current in this combination can be increased by a maximum factor of 2 to 3 in order to remain within the permitted voltage range of the output/flash voltage of max. 50V.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

Areas of application

This version is designed for switching and continuous operation at 24 VDC and has an additional switching input.

Control

A suitable external control signal, such as from a camera, PLC, or similar device, allows the illumination to be selectively switched on and off while power is supplied.

Flash operation

The variant is not suitable for flash operation with excessive currents.

Areas of application

This low-resistance version, optimized for flash operation, can also be used for switched, brightness-controlled, and continuous operation.

Required supply

One of the following power supplies is required for operation:

  • a lighting controller, e.g. from the IPSC/HPSC series, from Gefasoft or Gardasoft, or
  • a current source with current limiting.

Flash operation

Due to its low-resistance design, the SC version is particularly suitable for maximum current in flash operation. Compared to the 24-VDC types, output or flash voltages in the usual range up to a maximum of 50 V can be used.

As a result, the maximum flash current is typically significantly above the factor 2–3.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

06

Application, light guidance, and optics

Application and light guidance

Application and light guidance – HELIOS-130

Product inquiry

HELIOS-130 check for your application

Briefly describe your Prüfaufgabe.

Product: HELIOS-130

PDF Datasheet · Version 4.0

Select datasheet

HELIOS-130

Scope of the Data Sheet

The datasheet opens in a new tab. You can save it there as a PDF.