ARCUS-130-DL

Dunkelfeldbeleuchtungen

ARCUS-130-DL

  • Außen-/Innendurchmesser: 172/130mm
  • 2 LED-Reihen mit 128 LEDs
  • optional 4 oder 8 Segmente getrennt ansteuerbar
  • optional mit Diffusor erhältlich

Variants:

Inquire about product →Datasheet as PDF →

Specifications

Technical Specifications

01

General technical and commercial data

Design & Mechanics

Outer/inner diameter
172/130mm
Housing
Aluminum silver anodized
Front / Cover
PMMA
Weight
approx. 235 g (single layer SL version) approx. 340 g (double layer DL version)
LEDs
64 (SL Ausführung / SL version) / 128 (DL Ausführung / DL version)

Operation & Connection

Electrical versions and connections
  • 24 VDC · 1-channelM8 Connector 4-pin
  • 24 VDC with switching input · 1-channelM8 Connector 4-pin
  • SC · 1-channelM8 Connector 4-pin
  • 24 VDC · 2-channelM8 Connector 4-pin
  • SC · 2-channelM8 Connector 4-pin
  • 24 VDC · 4-channelM8 Connector 6-pin
  • SC · 4-channelM8 Connector 6-pin
  • 24 VDC · 8-channelM12 Connector 17-pin
  • SC · 8-channelM12 Connector 17-pin
Ambient Temperature
max. 50 °C recommended
Protection class (IP)
IP40
electrical protection class
III, safety extra-low voltage operation
Compliance
CE, RoHS
service life
The service life of LED lighting depends on many factors.
Service life explained in WikiLED →
02

Model-dependent characteristics

Model-dependent characteristics

In narrow view, the table can be shifted sideways.

variantCurrent and flash operationMeasured values and classification
Light colourWavelength / Color Temperaturenm / KBeam angleLED · °variantChannelsCurrent consumption24VDC type / max. Konstantstrom SC-TypMax. pulse current24VDC type / SC-Typ
t < 1 ms
Duty Cycle 1:10
IrradianceW/m² at constant currentElectrical powerWRisk groupEN 62471
Red615 nm120°DL1300 mA1,6 A29 W/m²8 Wexempt group
white5.800 K120°DL1520 mA4,0 A29 W/m²13 Wexempt group
Infrared850 nm120°DL1450 mA6,4 A–11 Wexempt group
Blue470 nm120°DL1540 mA4,0 A39 W/m²13 Wexempt group
Green525 nm120°DL–––––exempt group
Red615 nm120°DL2150 mA / Kanal0,8 A / Kanal29 W/m²8 Wexempt group
Red615 nm120°DL475 mA / Kanal0,4 A / Kanal29 W/m²8 Wexempt group
Red615 nm120°DL837,5 mA / Kanal0,2 A / Kanal29 W/m²8 Wexempt group
white5.800 K120°DL2260 mA / Kanal2 A / Kanal29 W/m²13 Wexempt group
white5.800 K120°DL4130 mA / Kanal1 A / Kanal29 W/m²13 Wexempt group
white5.800 K120°DL865 mA / Kanal0,5 A / Kanal29 W/m²13 Wexempt group
Infrared850 nm120°DL2225 mA / Kanal3,2 A / Kanal–11 Wexempt group
Infrared850 nm120°DL4112,5 mA / Kanal1,6 A / Kanal–11 Wexempt group
Infrared850 nm120°DL856,25 mA / Kanal0,8 A / Kanal–11 Wexempt group
Blue470 nm120°DL2270 mA / Kanal2 A / Kanal39 W/m²13 Wexempt group
Blue470 nm120°DL4135 mA / Kanal1 A / Kanal39 W/m²13 Wexempt group
Blue470 nm120°DL867,5 mA / Kanal0,5 A / Kanal39 W/m²13 Wexempt group

Notes on the specifications table

Messbedingungen gemäß Datasheet_Buechner_ARCUS-130_de_en_V3.0.pdf:

Page 2 – Characteristics:

Current consumption 24VDC-type ** / max. constant current SC-type **

max. pulse current 24VDC-type/ SC-type (t <1ms) *** on 24VDC<1ms

Beleuchtungsstärke **** Illumination Intensity ****

Power consumption at 24VDC Current demand at 24VDC

**** weitere Farben und Ausführungen von UV bis Infrarot auf Anfrage / other colours and types from UV to infrared on request **** angegebene Stromwerte sind als ungefähre Werte zu verstehen / stated current values should be considered as approximate values **** abhängig von den Blitzkonditionen, t <1ms / Duty Cycle 1:10 / depending on the strobe conditions, t <1ms / Duty Cycle 1:10 on on **** Cirka-Angaben im DC-Betrieb; Messabstand 16mm unter Gehäuseunterkante / approx. data in DC mode, Measuring distance 16mm below housing

03

Connection and PIN assignment

M8 Connector 4-pin · 24VDC · 1-channel

Connector drawing
PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-

M8 Connector 4-pin · 24VDC with switching input · 1-channel

Connector drawing

Front view of housing

PINFarbeWire colorFunction
1brownbrown+ 24V
3blueblue-
4blackblackSwitching input*

* ON: 3,7V (3mA) - 24V (30mA) / OFF: < 2,5V

M8 Connector 4-pin · SC · 1-channel

Connector drawing
PINFarbeWire colorFunction
4blackblack+
3blueblue-
04

Dimensional drawing

Dimensional drawing ARCUS-130-DL
05

Operating instructions

Areas of application

This version is designed for continuous operation at 24VDC.

Operating modes

  • DC operation on a suitable power supply with 24VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay
  • switched operation on a lighting controller (e.g. IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • brightness-controlled operation via lighting controller (IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply

Flash operation

Flash operation via controller (e.g., IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply. Depending on the lighting controller used and the maximum available output/flash voltage, the flash current in this combination can be increased by a maximum factor of 2 to 3 in order to remain within the permitted voltage range of the output/flash voltage of max. 50V.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

Areas of application

This version is designed for switching and continuous operation at 24 VDC and has an additional switching input.

Control

A suitable external control signal, such as from a camera, PLC, or similar device, allows the illumination to be selectively switched on and off while power is supplied.

Flash operation

The variant is not suitable for flash operation with excessive currents.

Areas of application

This low-resistance version, optimized for flash operation, can also be used for switched, brightness-controlled, and continuous operation.

Required supply

One of the following power supplies is required for operation:

  • a lighting controller, e.g. from the IPSC/HPSC series, from Gefasoft or Gardasoft, or
  • a current source with current limiting.

Flash operation

Due to its low-resistance design, the SC version is particularly suitable for maximum current in flash operation. Compared to the 24-VDC types, output or flash voltages in the usual range up to a maximum of 50 V can be used.

As a result, the maximum flash current is typically significantly above the factor 2–3.

Current limits

The maximum permissible currents for continuous and flash operation are also specified on the product label of the respective lighting.

24VDC type

Diese Ausführung ist für den Dauerbetrieb an 24VDC ausgelegt. Folgende Betriebsmodi sind möglich:

  • DC operation on a suitable power supply with 24VDC
  • switched operation on a suitable power supply via e.g. PLC, opto-relay
  • switched operation on a lighting controller (e.g. IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • brightness-controlled operation via lighting controller (IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply
  • Flash operation via controller (e.g., IPSC/HPSC or Gardasoft) in conjunction with a suitable power supply. Depending on the lighting controller used and the maximum available output/flash voltage, the flash current in this combination can be increased by a maximum factor of 2 to 3 in order to remain within the permitted voltage range of the output/flash voltage of max. 50V.

SC type

Diese für den Blitzbetrieb optimierte Ausführung ist auch für den geschalteten oder helligkeitsgesteuerten bzw. Dauerbetrieb einsetzbar. Für den Betrieb ist ein Beleuchtungscontroller, z.B. die IPSC/HPSC-Serie oder Gardasoft, notwendig. Die SC-Ausführung ist aufgrund der niederohmigen Auslegung insbesondere für die maximale Bestromung im Blitzbetrieb geeignet da im Vergleich zu den 24VDC-Typen mit Ausgangs-/Blitzspannungen im üblichen Bereich bis maximal 50V gearbeitet werden kann. Dadurch liegt der maximale Blitzstrom typischerweise deutlich oberhalb des Faktors 2-3.

06

Application, light guidance, and optics

Ausführungen and Segmentsteuerung

Ausführungen and Segmentsteuerung – ARCUS-130-DL

Dark field application example (ARCUS-130-DL)

Dark field application example (ARCUS-130-DL) – ARCUS-130-DL

Product inquiry

ARCUS-130-DL check for your application

Briefly describe your Prüfaufgabe.

Product: ARCUS-130-DL

PDF Datasheet · Version 4.0

Select datasheet

ARCUS-130-DL

Scope of the Data Sheet

The datasheet opens in a new tab. You can save it there as a PDF.